Ti6Al4V合金表面含钽TiO2薄膜的溶胶-凝胶法制备、耐蚀性和亲水性

来源期刊:中国有色金属学报(英文版)2015年第2期

论文作者:付 涛 孙见敏 Zafer ALAJMI 吴 锋

文章页码:471 - 476

Key words:titanium; TiO2; sol-gel; tantalum; corrosion; hydrophilicity

摘    要:配制含5%、20%和33%(摩尔分数)钽的二氧化钛溶胶,采用浸提法在表面粗化的Ti6Al4V合金表面涂覆含钽TiO2溶胶-凝胶薄膜。经过1.5 mol/L NaOH-HCl预处理基体表面的含钽TiO2薄膜附着较好,但含33%Ta的试样出现了裂纹。X射线光电子谱分析表明,钛和钽在薄膜中以TiO2、Ta2O5形式存在,未检测到铝元素。X射线衍射和拉曼散射分析表明,钽的加入降低了膜层的结晶性。在无钙Hank’s平衡盐液中的动电位极化实验表明,与抛光试样相比,涂层试样的耐蚀性显著改善。钽的加入对涂层试样的紫外光致亲水性转变有阻碍作用。含20% Ta的试样具有足够的膜层完整性和亲水性转化速率,可望具有较好的生物学性能。

Abstract: Ta-containing TiO2 films with Ta contents of 5%, 20%, 33% (mole fraction) were sol-gel coated on the surface roughened Ti6Al4V alloy by dip coating method for biomedical applications. The Ta-TiO2 films on 1.5 mol/L NaOH-HCl pretreated substrate are adherent, but there are cracks for the sample with 33% Ta. X-ray photoelectron spectroscopy results show that Ti and Ta exist as TiO2 and Ta2O5 in the film, and Al element is not detectable. X-ray diffraction and Raman scattering analyses reveal that the addition of Ta decreases crystallization of the films. Potentiodynamic polarization test in a Ca-free Hank’s balanced solution demonstrates that the coating samples markedly improve the corrosion resistance compared with the polished sample. The addition of Ta impedes UV light-induced hydrophilic conversion of the coating samples. The sample with 20% Ta has enough film integrity and hydrophilic conversion rate, and is expected to possess good biological properties.