简介概要

Application of X-ray Computed Tomography in Characterization Microstructure Changes of Cement Pastes in Carbonation Process

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition2012年第2期

论文作者:韩建德 孙伟

文章页码:358 - 363

摘    要:The microstructure characteristics and meso-defect volume changes of hardened cement paste before and after carbonation were investigated by three-dimensional(3D)X-ray computed tomography(XCT),where three types water-to-cement ratio of 0.53,0.35 and 0.23 were considered.The high-resolution 3D images of microstructure and filtered defects were reconstructed by an XCT VG Studio MAX 2.0 software.The meso-defect volume fractions and size distribution were analyzed based on 3D images through add-on modules of 3D defect analysis.The 3D meso-defects volume fractions before carbonation were 0.79%,0.38% and 0.05% corresponding to w/c ratio=0.53,0.35 and 0.23,respectively.The 3D meso-defects volume fractions after carbonation were 2.44%,0.91% and 0.14% corresponding to w/c ratio=0.53,0.35 and 0.23,respectively.The experimental results suggest that 3D meso-defects volume fractions after carbonation for above three w/c ratio increased significantly.At the same time,meso-cracks distribution of the carbonation shrinkage and gray values changes of the different w/c ratio and carbonation reactions were also investigated.

详情信息展示

Application of X-ray Computed Tomography in Characterization Microstructure Changes of Cement Pastes in Carbonation Process

韩建德1,2,孙伟1,2

1. School of Materials Science and Engineering,Southeast University

摘 要:The microstructure characteristics and meso-defect volume changes of hardened cement paste before and after carbonation were investigated by three-dimensional(3D)X-ray computed tomography(XCT),where three types water-to-cement ratio of 0.53,0.35 and 0.23 were considered.The high-resolution 3D images of microstructure and filtered defects were reconstructed by an XCT VG Studio MAX 2.0 software.The meso-defect volume fractions and size distribution were analyzed based on 3D images through add-on modules of 3D defect analysis.The 3D meso-defects volume fractions before carbonation were 0.79%,0.38% and 0.05% corresponding to w/c ratio=0.53,0.35 and 0.23,respectively.The 3D meso-defects volume fractions after carbonation were 2.44%,0.91% and 0.14% corresponding to w/c ratio=0.53,0.35 and 0.23,respectively.The experimental results suggest that 3D meso-defects volume fractions after carbonation for above three w/c ratio increased significantly.At the same time,meso-cracks distribution of the carbonation shrinkage and gray values changes of the different w/c ratio and carbonation reactions were also investigated.

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号