Effect of Ball Scribing on Power Loss Separation of Fe-3%Si Grain-oriented Silicon Steel

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition2016年第2期

论文作者:王浩 李长生 ZHAN Jianbo YU Zhenhua JI Yafeng WANG Guanglei PERIN Deniz

文章页码:435 - 439

摘    要:Power loss of Fe-3%Sigrain-oriented silicon steelwas measured after ballscribing with different spacing using a self-designed tool.Three different sections of power loss,including hysteresis loss,abnormalloss,and eddy current loss,were measured and calculated,respectively.The loss variation and ratio were analyzed based on the experimentaldata.At 1.0 T,hysteresis loss of tested steelwith scribing spacing of 8 mm descends by 8.2% compared to samples without scribing,which is similar to the totalloss variation,and abnormalloss descends by 16.8%.At 1.0 T,hysteresis loss ratio of the steelwith scribing spacing of 16 mm ascends from 55.7% to 57.9%,and eddy current loss increases from 17.4% to 24.1%,while abnormalloss descends from 26.9% to 23.7%.The experimentalresults show that the reduction of power loss after scribing is mainly due to decreasing of hysteresis loss and abnormalloss.

详情信息展示

Effect of Ball Scribing on Power Loss Separation of Fe-3%Si Grain-oriented Silicon Steel

王浩1,2,李长生2,ZHAN Jianbo1,YU Zhenhua1,JI Yafeng3,WANG Guanglei4,PERIN Deniz5

1. Materials Research Institute,Technical Center of China Tobacco Yunnan Industrial Co.,Ltd.2. State Key Laboratory of Rolling and Automation,Northeastern University3. Engineering Research Center for Department of Heavy Machinery Education,Taiyuan University of Science and Technology4. Nanjing Iron and Steel Co.Ltd.5. Department of Physics,Balikesir University

摘 要:Power loss of Fe-3%Sigrain-oriented silicon steelwas measured after ballscribing with different spacing using a self-designed tool.Three different sections of power loss,including hysteresis loss,abnormalloss,and eddy current loss,were measured and calculated,respectively.The loss variation and ratio were analyzed based on the experimentaldata.At 1.0 T,hysteresis loss of tested steelwith scribing spacing of 8 mm descends by 8.2% compared to samples without scribing,which is similar to the totalloss variation,and abnormalloss descends by 16.8%.At 1.0 T,hysteresis loss ratio of the steelwith scribing spacing of 16 mm ascends from 55.7% to 57.9%,and eddy current loss increases from 17.4% to 24.1%,while abnormalloss descends from 26.9% to 23.7%.The experimentalresults show that the reduction of power loss after scribing is mainly due to decreasing of hysteresis loss and abnormalloss.