简介概要

Analysis and optimization of heat loss for water-cooled furnace roller

来源期刊:中南大学学报(英文版)2013年第8期

论文作者:LI Yong(李勇) LI Jia-dong(李家栋) LIU Yu-jia(刘宇佳) HOU Shuai(侯帅) WANG Zhao-dong(王昭东) WANG Guo-dong(王国栋)

文章页码:2158 - 2164

Key words:furnace roller; water-cooled furnace; heat loss; optimization; control

Abstract: A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller’s structure. The complicated model was solved with iteration planning algorithm based on Newton search. The model is proved logical and credible by comparing calculated results and measured data. Then, the relationship between water flow velocity, inlet water temperature, furnace temperature and roller cross section temperature, outlet water temperature, water temperature rise, cooling water heat absorption was studied. The conclusions and recommendations are mainly as follows: 1) Cooling water temperature rise decreases with the increase of water flow velocity, but it has small relationship with inlet water temperature; 2) In order to get little water scale, inlet water temperature should be controlled below 30 °C. 3) The cooling water flow velocity should be greater than critical velocity. The critical velocity is 0.07 m/s and water flow velocity should be controlled within 0.4-0.8 m/s. Within this velocity range, water cooling efficiency is high and water temperature rise is little. If cooling water velocity increases again, heat loss will increase, leading to energy wasting.

详情信息展示

Analysis and optimization of heat loss for water-cooled furnace roller

LI Yong(李勇), LI Jia-dong(李家栋), LIU Yu-jia(刘宇佳), HOU Shuai(侯帅), WANG Zhao-dong(王昭东), WANG Guo-dong(王国栋)

(State Key Laboratory of Rolling and Automation (Northeastern University), Shenyang 110819, China)

Abstract:A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller’s structure. The complicated model was solved with iteration planning algorithm based on Newton search. The model is proved logical and credible by comparing calculated results and measured data. Then, the relationship between water flow velocity, inlet water temperature, furnace temperature and roller cross section temperature, outlet water temperature, water temperature rise, cooling water heat absorption was studied. The conclusions and recommendations are mainly as follows: 1) Cooling water temperature rise decreases with the increase of water flow velocity, but it has small relationship with inlet water temperature; 2) In order to get little water scale, inlet water temperature should be controlled below 30 °C. 3) The cooling water flow velocity should be greater than critical velocity. The critical velocity is 0.07 m/s and water flow velocity should be controlled within 0.4-0.8 m/s. Within this velocity range, water cooling efficiency is high and water temperature rise is little. If cooling water velocity increases again, heat loss will increase, leading to energy wasting.

Key words:furnace roller; water-cooled furnace; heat loss; optimization; control