简介概要

Up-conversion fluorescence biosensor for sensitive detection of CA-125 tumor markers

来源期刊:Journal of Rare Earths2019年第9期

论文作者:Jingshi Liu Sai Xu Liheng Sun Songtao Hu Jiao Sun Min Liu Cui Ma Haipeng Liu Ziqing Wang Ying Yang Biao Dong Decheng Hong

文章页码:943 - 948

摘    要:Sensitive and specific bioassays of tumor markers are critical for early cancer detection and treatment. In recent years, lanthanide(Ln3+) doped upconversion nanoparticles(UCNPs) have attracted wide attentions in tumor markers detectio n. Herein, we co mbined NaYF4:Yb,Tm and silver nanoparticles, serving as energy donor and receptor, respectively, to form an up-conversion fluorescence based inhibitory tumor marker biosensor system. The tumor marker CA-125 molecules are labeled with silver NPs, and the energy transfer fluorescent signal can be detected between the UCNPs and the silver NP receptors. The biosensor shows good stability, high sensitivity and selectivity in the tumor marker concentration range from 5 to 100 ng/mL, as well as a detection limit of 120 pg/mL. Due to the advantage of ease of fabrication and operation, low cost and high information capacity, this technology holds great potential for the clinical applications.

详情信息展示

Up-conversion fluorescence biosensor for sensitive detection of CA-125 tumor markers

Jingshi Liu,Sai Xu,Liheng Sun,Songtao Hu,Jiao Sun,Min Liu,Cui Ma,Haipeng Liu,Ziqing Wang,Ying Yang,Biao Dong,Decheng Hong

摘 要:Sensitive and specific bioassays of tumor markers are critical for early cancer detection and treatment. In recent years, lanthanide(Ln3+) doped upconversion nanoparticles(UCNPs) have attracted wide attentions in tumor markers detectio n. Herein, we co mbined NaYF4:Yb,Tm and silver nanoparticles, serving as energy donor and receptor, respectively, to form an up-conversion fluorescence based inhibitory tumor marker biosensor system. The tumor marker CA-125 molecules are labeled with silver NPs, and the energy transfer fluorescent signal can be detected between the UCNPs and the silver NP receptors. The biosensor shows good stability, high sensitivity and selectivity in the tumor marker concentration range from 5 to 100 ng/mL, as well as a detection limit of 120 pg/mL. Due to the advantage of ease of fabrication and operation, low cost and high information capacity, this technology holds great potential for the clinical applications.

关键词:

<上一页 1 下一页 >

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号