double linear strain distribution assumption of RC beam strengthened with external-bonded or near-surface mounted fiber reinforced plastic

来源期刊:中南大学学报(英文版)2012年第12期

论文作者:Ren Zhen-hua (任振华) Liu Han-long (刘汉龙) Zhou feng-jun (周丰峻)

文章页码:3582 - 3594

Key words:double linear strain distribution assumption; external-bonded structure, near-surface mounted structure; fiber reinforced plastic; strengthening; concrete beam

Abstract: Rehabilitation of existing structures with fiber reinforced plastic (FRP) has been growing in popularity because they offer superior performance in terms of resistance to corrosion and high specific stiffness. The strain coordination results of 34 reinforced concrete beams (four groups) strengthened with different methods were presented including external-bonded or near-surface mounted glass or carbon FRP or helical rib bar in order to study the strain coordination of the strengthening materials and steel rebar of RC beam. Because there is relative slipping between concrete and strengthening materials (SM), the strain of SM and steel rebar of RC beam satisfies the double linear strain distribution assumption, that is, the strain of longitudinal fiber parallel to the neutral axis of plated beam within the scope of effective height (h0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. the strain of SM and steel rebar satisfies the equation , where the value of β is equal to 1.1-1.3 according to the test results.

详情信息展示

double linear strain distribution assumption of RC beam strengthened with external-bonded or near-surface mounted fiber reinforced plastic

Ren Zhen-hua (任振华) 1, Liu Han-long (刘汉龙) 1, Zhou feng-jun (周丰峻)2

(1.Key Laboratory of Ministry of Education for Geomechanics and Embankment Engineering
(Hohai University), Nanjing 210098, China;
2. The fourth Engineer Scientific Research Institute of the Headquarters of the General Staff, Beijing 100850, China)

Abstract:Rehabilitation of existing structures with fiber reinforced plastic (FRP) has been growing in popularity because they offer superior performance in terms of resistance to corrosion and high specific stiffness. The strain coordination results of 34 reinforced concrete beams (four groups) strengthened with different methods were presented including external-bonded or near-surface mounted glass or carbon FRP or helical rib bar in order to study the strain coordination of the strengthening materials and steel rebar of RC beam. Because there is relative slipping between concrete and strengthening materials (SM), the strain of SM and steel rebar of RC beam satisfies the double linear strain distribution assumption, that is, the strain of longitudinal fiber parallel to the neutral axis of plated beam within the scope of effective height (h0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. the strain of SM and steel rebar satisfies the equation , where the value of β is equal to 1.1-1.3 according to the test results.

Key words:double linear strain distribution assumption; external-bonded structure, near-surface mounted structure; fiber reinforced plastic; strengthening; concrete beam

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号