Solid-phase extraction of trace Au(Ⅲ) with SDG and determination by the catalytic spectrophotometric method

来源期刊:Rare Metals2008年第6期

论文作者:LI Huizhia and ZHAI Yubob a School of Chemistry and Chemical Engineering, Jinan University, Jinan , China b School of Life Science, Nanjing University, Nanjing , China

文章页码:560 - 565

摘    要:The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in mi- croemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(III) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(III) ions. The method has been applied to the determination of trace gold with satisfactory results.

详情信息展示

Solid-phase extraction of trace Au(Ⅲ) with SDG and determination by the catalytic spectrophotometric method

LI Huizhia and ZHAI Yubob a School of Chemistry and Chemical Engineering, Jinan University, Jinan 250022, China b School of Life Science, Nanjing University, Nanjing 210093, China

摘 要:The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in mi- croemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(III) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(III) ions. The method has been applied to the determination of trace gold with satisfactory results.

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号