简介概要

Evaluation of D113 cation exchange resin for the removal of Eu(Ⅲ) from aqueous solution

来源期刊:JOURNAL OF RARE EARTHS2010年第6期

论文作者:熊春华 郑展望

文章页码:862 - 867

摘    要:Batch adsorption experiments were conducted for the adsorption of Eu(Ⅲ) ions from aqueous solution by D113 resin. The results indicated that D113 resin could adsorb Eu(Ⅲ) ion effectively from aqueous solution. The adsorption was strongly dependent on pH of the medium with enhanced adsorption as the pH turned from 3.50 to 7.00 and the optimal adsorption condition was in HAc-NaAc medium with pH value of 6.50. The maximum uptake capacity of Eu(Ⅲ) ions was 290.9 mg/g D113 at 298 K, at an initial pH value of 6.50. The overall adsorption process was best described by Lagergren-first-order kinetics. When Freundlich and Langmuir isotherms were tested, the latter had a better fit with the experimental data. The thermodynamic parameters such as free energy (G) which were all negative, indicated that the adsorption of Eu(Ⅲ) ions onto D113 resin was spontaneous and the positive value of enthalpy (H) showed that the adsorption was endothermic in nature. Thomas model was applied to experimental column data to determine the characteristic parameters of column useful for process design. Furthermore, Eu(Ⅲ) could be eluted by using 3.0 mol/L HCl solution and the D113 resin could be regenerated and reused.

详情信息展示

Evaluation of D113 cation exchange resin for the removal of Eu(Ⅲ) from aqueous solution

熊春华,郑展望

Department of Applied Chemistry, Zhejiang Gongshang University

摘 要:Batch adsorption experiments were conducted for the adsorption of Eu(Ⅲ) ions from aqueous solution by D113 resin. The results indicated that D113 resin could adsorb Eu(Ⅲ) ion effectively from aqueous solution. The adsorption was strongly dependent on pH of the medium with enhanced adsorption as the pH turned from 3.50 to 7.00 and the optimal adsorption condition was in HAc-NaAc medium with pH value of 6.50. The maximum uptake capacity of Eu(Ⅲ) ions was 290.9 mg/g D113 at 298 K, at an initial pH value of 6.50. The overall adsorption process was best described by Lagergren-first-order kinetics. When Freundlich and Langmuir isotherms were tested, the latter had a better fit with the experimental data. The thermodynamic parameters such as free energy (G) which were all negative, indicated that the adsorption of Eu(Ⅲ) ions onto D113 resin was spontaneous and the positive value of enthalpy (H) showed that the adsorption was endothermic in nature. Thomas model was applied to experimental column data to determine the characteristic parameters of column useful for process design. Furthermore, Eu(Ⅲ) could be eluted by using 3.0 mol/L HCl solution and the D113 resin could be regenerated and reused.

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号