石墨炉原子吸收测定地球化学样品中痕量金
来源期刊:有色金属科学与工程2011年第6期
论文作者:赖秋祥
文章页码:89 - 92
关键词:痕量金;石墨炉原子吸收光谱仪;地球化学样品
Key words:trace gold; graphite furnace atomic absorption ; geochmical samples
摘 要:试样经灼烧,用王水加热分解,并在Fe3+存在下,于王水介质中用泡沫塑料吸附Au;吸附Au后的泡沫塑料再用10 g/L硫脲溶液解脱,采用斜坡升温技术在220ZS石墨炉原子吸收光谱仪测定超痕量金根据实验得出最佳分析条件,该方法捡出限为0.1 ng/g,精密度(RSD,n=12)4.2%~10.8%,经国家一级标准物质分析验证,结果与标准值相符。
Abstract:
The geochemical exploration sample was roasted and dissolved with aqua regia. The trace gold is absorbed by polyurethane foam from aqua regia medium under the presence of Fe3+ and released in 10 g/L thiourea solution. The trace gold is determined by GFAAS with the slope warming. The detection limit of the method is 0.1 ng/g with the precision (RSD, n,=12) of 4.2%~10.8 %. The results conform to the certified values through the national standard reference material tests.