ELECTRIC RESISTANCE MEASUREMENT OF CARBON FIBRE SMART CONCRETE

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition1995年第4期

论文作者:赵斌元 李卓球 吴代华

文章页码:52 - 56

摘    要:<正>After having measured the electric resistanceof carbon firbre reinforced concrete (CFRC) by applying aD. C. current,it was found that the current passing throughthe specimen under a constant voltage decreased with thetime,and if changing the value of voltage, the electric resis-tance was obviously affected. When current flew through thespecimen, polarisation emerged under a high votage (> 5v),but that could be neglected under a low voltage (<5v).

详情信息展示

ELECTRIC RESISTANCE MEASUREMENT OF CARBON FIBRE SMART CONCRETE

赵斌元,李卓球,吴代华

摘 要:<正>After having measured the electric resistanceof carbon firbre reinforced concrete (CFRC) by applying aD. C. current,it was found that the current passing throughthe specimen under a constant voltage decreased with thetime,and if changing the value of voltage, the electric resis-tance was obviously affected. When current flew through thespecimen, polarisation emerged under a high votage (> 5v),but that could be neglected under a low voltage (<5v).