Passive cooling of porous tile used on external wall
来源期刊:中南大学学报(英文版)2009年第z1期
论文作者:罗庆 刘庆开 夏煦
文章页码:135 - 139
Key words:porous material; external wall; passive cooling; building energy efficiency
Abstract: The porous tiles under the dry and wet conditions were studied. The simplified mathematical model was put forward to simulate the procedure of moisture evaporating for the densely porous tile. The results show that the capability of passive cooling of the porous tile is more than 5 ℃ with moisture content of 30% in Yangtze river region. Through the comparison between the measuring and simulating data,it can be proved that the simplified math model can be fully used to the engineering application,which provides a reference to explore the thermal performance of other porous material.