简介概要

微乳液-鲁米诺-H2O2-钴(化学发光法测定废水中痕量钴(Ⅱ)

来源期刊:冶金分析2011年第6期

论文作者:姚坡 刘娟 鲁琛琛 李绍卿

文章页码:62 - 65

关键词:微乳液; 化学发光法; 钴; 废水

Key words:microemulsion; chemiluminesence method; cobalt; wastewater

摘    要:基于微乳液有增稳、增敏、增溶等作用,建立了微乳液-鲁米诺-H2O2-Co(Ⅱ)化学发光体系测定Co(Ⅱ)的分析方法。该法测定Co(浓度范围为1.0×10-9~1.0×10-6 mg/mL,检出限为9.15×10-10 mg/mL。测定制药废水中痕量钴,该方法与火焰原子吸收光谱法结果一致,相对标准偏差(n=5)为1.0%~2.5%。

Abstract: Based on the stabilization,sensitization and solubilization effect of microemulsion,the determination of cobalt Ⅱ by chemiluminesence method with microemulsion-luminol-hydrogen peroxide-Co Ⅱ system was established.This method could be used to effectively determine CoⅡ in the range of 1×10-9-1×10-6 mg/mL with detection limit of 9.15×10-10 mg/mL.The method has been applied to the determination of trace cobalt Ⅱ in pharmaceutical waste water samples.The results were consistent with those obtained by flame atomic absorption spectrometry,and the relative standard deviations (RSD,n=5) was 1.0%-2.5%.

详情信息展示

微乳液-鲁米诺-H2O2-钴(化学发光法测定废水中痕量钴(Ⅱ)

姚坡1,刘娟2,鲁琛琛3,李绍卿3

(1.山东省济南市山东省环境保护科学研究设计院
2.中海油山东化学工程有限责任公司,山东济南 250013
3.长安大学环境科学与工程学院,陕西西安 710064)

摘 要:基于微乳液有增稳、增敏、增溶等作用,建立了微乳液-鲁米诺-H2O2-Co(Ⅱ)化学发光体系测定Co(Ⅱ)的分析方法。该法测定Co(浓度范围为1.0×10-9~1.0×10-6 mg/mL,检出限为9.15×10-10 mg/mL。测定制药废水中痕量钴,该方法与火焰原子吸收光谱法结果一致,相对标准偏差(n=5)为1.0%~2.5%。

关键词:微乳液; 化学发光法; 钴; 废水

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号