简介概要

列车交会空气压力波测量的影响因素

来源期刊:中南大学学报(自然科学版)2004年第5期

论文作者:梁习锋 陈燕荣

文章页码:810 - 814

关键词:实车试验;空气压力测量;交会空气压力波

Key words:real train test; air pressure measurement; crossing air pressure pulse

摘    要:研究了连接动态压力传感器的信号线长度、放大器的滤波频率和数据采集系统的采样频率对空气压力波测量的影响。研究结果表明,当传感器信号线长度小于100 m时,对传感器输出的动态信号影响不大于1%,满足列车交会空气压力波实车测量要求;放大器的滤波频率和数采系统采样频率对空气压力波的测试结果均有较大影响,应采用带低通的应变放大器,滤波频率以100 Hz为宜;随着采样频率的增加,测量得到的空气压力波幅值增大,采样频率增加到1 kHz后,测量结果趋于稳定。在列车交会空气压力波实车测试中,为保证测试的准确性,节 省设备内存空间,采样频率取1 kHz较合适。

Abstract: The effects of the signal line length, the filter and the sampling frequencies on measuring air pressure pulse were studied in this paper. The results show that when the signal line length of sensor is less than 100 m, its influence on sensor dynamic signal will be less than 1%. It meets the real train test requirement of measuring crossing air pressure pulse. The filter and the sampling frequencies have evident influence on the results of measuring air pressure pulse, so the strain gauge magnifier with the low-pass, and whose filter frequency 100 Hz is supposed to be adopted for measuring crossing air pressure pulse of real train test. It also shows that the measured magnitude of air pressure pulse increases with increasing the sampling frequency until the sampling frequency reaches 1 kHz. In order to reach the factuality of the wave shape and save memory the sampling frequency should be set at 1 kHz.

详情信息展示

 

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号