简介概要

Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation

来源期刊:JOURNAL OF RARE EARTHS2004年第2期

论文作者:江祖成 胡斌 Ruth Wanjau 何蔓 梁沛 秦永超

Key words:chemical analysis; fluorination-electrothermal vaporization; HPLC; P507 resin; cerium oxide; rare earths;

Abstract: A new method for the separation and detection of trace metal impurities in cerium oxide(CeO2)using HPLC combined with electrothermal vaporization(ETV)-ICP-AES was developed.This combination links the high separation power of HPLC and high sensitivity of ETV-ICP-AES.The 2-ethylhexyl hydrogen 2-ethylhexylphosphate(P507)resin was used as stationary phase for the separation of metallic impurities in order to eliminate severe spectral interferences of the matrix.The dilute nitric acid was adopted as mobile phase for eluting Cu,Mn,Ni and La.The separation process can be accomplished in about 30 min.After concentrating the eluate by evaporation,the trace impurities were determined by using ETV-ICP-AES with the addition of 6% PTFE slurry as chemical modifier.The proposed method was applied to the analysis of CeO2 with satisfactory recoveries.

详情信息展示

Determination of Trace Metal Impurities in Cerium Oxide by Fluorination-Assisted ETV-ICP-AES after HPLC Separation

江祖成1,胡斌1,Ruth Wanjau1,何蔓1,梁沛1,秦永超1

(1.Department of Chemistry,Wuhan University,Wuhan 430072,China)

Abstract:A new method for the separation and detection of trace metal impurities in cerium oxide(CeO2)using HPLC combined with electrothermal vaporization(ETV)-ICP-AES was developed.This combination links the high separation power of HPLC and high sensitivity of ETV-ICP-AES.The 2-ethylhexyl hydrogen 2-ethylhexylphosphate(P507)resin was used as stationary phase for the separation of metallic impurities in order to eliminate severe spectral interferences of the matrix.The dilute nitric acid was adopted as mobile phase for eluting Cu,Mn,Ni and La.The separation process can be accomplished in about 30 min.After concentrating the eluate by evaporation,the trace impurities were determined by using ETV-ICP-AES with the addition of 6% PTFE slurry as chemical modifier.The proposed method was applied to the analysis of CeO2 with satisfactory recoveries.

Key words:chemical analysis; fluorination-electrothermal vaporization; HPLC; P507 resin; cerium oxide; rare earths;

【全文内容正在添加中】

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号