Abstract: The structure of the thermocouple used to measure temperature of aluminium cells by dynamic method has been investigated. In order to meet the requirement of temperature measurement error a new thermocouple was designed. The results verified that heat insulation material in protective tubes can reduce the error of temperature measurement by dynamic method.