简介概要

Thermal-environment characteristics and comfort of combined radiant-floor (Korean heating system ondol) and convective cooling system

来源期刊:中南大学学报(英文版)2013年第12期

论文作者:LEE Kang-Guk HONG Won-Hwa

文章页码:3589 - 3603

Key words:convection cooling; temperature; ondol; thermal comfort; fan coil unit; combined cooling system

Abstract: The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating panel typically applied to apartments in South Korea with the forced-convection cooling system using improved fan coil unit. The subjective warm/cool-feeling responses to the combined radiant-floor and convective cooling system in the questionnaire survey conducted among the test subjects were analyzed to establish the basic data for the combined cooling system. The results show that in the thermal-equilibrium condition, the vertical air temperature difference in the model living room is larger in the forced-convection-cooling condition. Most of the subjects feel a proper warm/cool feeling on their entire body, but they feel colder on the foot and lower body in the combined-cooling condition.

详情信息展示

Thermal-environment characteristics and comfort of combined radiant-floor (Korean heating system ondol) and convective cooling system

LEE Kang-Guk, HONG Won-Hwa

(School of Architecture, Kyungpook National University, 1370 Sangyeok-dong Buk-gu, Daegu, Korea)

Abstract:The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating panel typically applied to apartments in South Korea with the forced-convection cooling system using improved fan coil unit. The subjective warm/cool-feeling responses to the combined radiant-floor and convective cooling system in the questionnaire survey conducted among the test subjects were analyzed to establish the basic data for the combined cooling system. The results show that in the thermal-equilibrium condition, the vertical air temperature difference in the model living room is larger in the forced-convection-cooling condition. Most of the subjects feel a proper warm/cool feeling on their entire body, but they feel colder on the foot and lower body in the combined-cooling condition.

Key words:convection cooling; temperature; ondol; thermal comfort; fan coil unit; combined cooling system