简介概要

Determination of trace amounts of silver(I) in the presence of an activator with a kinetic method

来源期刊:Rare Metals2014年第6期

论文作者:Shahryar Abbasi Hadi Barzegaramiri Abbas Farmany

文章页码:731 - 736

摘    要:A simple and sensitive kinetic-spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10-phenantroline as activator. The absorbance was measured at 525 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng ml-1of silver with good precision and accuracy, and the detection limit is down to0.125 ng ml-1. The relative standard deviation for a standard solution of 25.0 ng ml-1of silver is 1.36 %(n = 10).The proposed method proves to be highly sensitive,selective, and relatively rapid for the assay of silver at lowlevel range of 0.3–50.0 ng ml-1without any pre-concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory.

详情信息展示

Determination of trace amounts of silver(I) in the presence of an activator with a kinetic method

Shahryar Abbasi1,Hadi Barzegaramiri1,Abbas Farmany2

1. Department of Chemistry, Ilam University2. Department of Chemistry, Islamic Azad University

摘 要:A simple and sensitive kinetic-spectrophotometric method was developed for the determination of trace amounts of silver, based on its catalytic effect on the oxidation of azocarmine G by peroxydisulfate in sulfuric acid medium and at 30 °C in the presence of 1,10-phenantroline as activator. The absorbance was measured at 525 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature, ionic strength, and interferences was also investigated. The calibration curve is linear over the concentration range 0.3–50.0 ng ml-1of silver with good precision and accuracy, and the detection limit is down to0.125 ng ml-1. The relative standard deviation for a standard solution of 25.0 ng ml-1of silver is 1.36 %(n = 10).The proposed method proves to be highly sensitive,selective, and relatively rapid for the assay of silver at lowlevel range of 0.3–50.0 ng ml-1without any pre-concentration and separation step. The method was applied for the determination of silver in river water and white photographic film. The analytic results of the real samples are in excellent agreement with atomic absorption spectrometry analysis. The analytical results obtained are satisfactory.

关键词:

<上一页 1 下一页 >

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号