简介概要

Spectrofluorimetric determination of terbium with terephthalic acid

来源期刊:Rare Metals2002年第4期

论文作者:ZHAO Guohu and ZHAO JunBasic Science Department, Gansu Agricultural University, Lanzhou , China

文章页码:255 - 259

摘    要:<正>A spectrofluorimetric method has been developed for the determination of terbium(III) based on the formation ofa complex with terephthalic acid [benzene-1,4-dicarboxylic acid (TPA)] in slighdy acidic aqueous solution in the presenceof gelatin. Terbium ion can form a stable complex with TPA with the stoichiometry of 1:2. The best excitation and maxi-mum emission wavelengths are observed at 260 nm and 545 nm, respectively. The fluorescence intensity of terbium com-plex gets the strongest within 20 min and remains stable up to 10 h, and it is proportional to terbium(III) concentration in therange of 4.0×10-5-1.6×10-7 mol·L-1 under the optimum conditions. The fluorescence system has good selectivity, sensitivityand stability. The relative standard deviation is still within ±4% in the presence of 1200-fold amounts of the other lanthanideions when the concentration of terbium(III) is 1.0×10-6 mol·L-1 and common co-existing ions hardly interfere the determi-nation. It has been applied to the direct fiuori

详情信息展示

Spectrofluorimetric determination of terbium with terephthalic acid

摘要:<正>A spectrofluorimetric method has been developed for the determination of terbium(III) based on the formation ofa complex with terephthalic acid [benzene-1,4-dicarboxylic acid (TPA)] in slighdy acidic aqueous solution in the presenceof gelatin. Terbium ion can form a stable complex with TPA with the stoichiometry of 1:2. The best excitation and maxi-mum emission wavelengths are observed at 260 nm and 545 nm, respectively. The fluorescence intensity of terbium com-plex gets the strongest within 20 min and remains stable up to 10 h, and it is proportional to terbium(III) concentration in therange of 4.0×10-5-1.6×10-7 mol·L-1 under the optimum conditions. The fluorescence system has good selectivity, sensitivityand stability. The relative standard deviation is still within ±4% in the presence of 1200-fold amounts of the other lanthanideions when the concentration of terbium(III) is 1.0×10-6 mol·L-1 and common co-existing ions hardly interfere the determi-nation. It has been applied to the direct fiuori

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号