共搜索到11372条信息,每页显示10条信息,共1138页。用时:0小时0分0秒614毫秒
with the available experimental data. Key words: Cu-Cd; phase diagram; thermodynamic assessment  ... and in the central part of the phase diagram, which was 314 ℃, 97.9% Cd and 544 ℃, 47.3% Cd respectively. All data concerning invariant reactions used for the assessment procedure are shown in Table 2. Table 2......
J. Cent. South Univ. (2020) 27: 221-230 DOI: https://doi.org/10.1007/s11771-020-4290-5 3D stability assessment of stepped slopes in inhomogeneous soils LI Xiong-wei(李雄威)1, ZHU Jian-qun(朱建群)1, LI... University, Changsha 410075, China Central South University Press and Springer-Verlag GmbH Germany, part of Springer Nature 2020 Abstract: Stability assessment of slopes has historically been performed......
surface cracked tensile plates made of 2219-T87 Al alloy at cryogenic temperatures were correlated using a modified inherent flaw model. Fracture parameters to generate the failure assessment diagram... center–surface cracked tensile specimens having different thicknesses. The failure assessment diagram of a material generated from tensile fracture plate configuration can be applied to failure pressure......
Determination and application of stress-based forming limit diagram in aluminum tube hydroforming ZHOU Lin (周林), XUE Ke-min (薛克敏), LI Ping (李萍) School of Materials Science and Engineering, Hefei... diagram(FLSD) established with limit stress is independent of the strain paths. Compared with traditional strain-based forming limit diagram(FLD), it is more convenient and practical to use......
Pressure-impulse diagram with multiple failure modes of one-way reinforced concrete slab under blast loading using SDOF methodWANG Wei(汪维)1,2, ZHANG Duo(张舵)1, LU Fang-yun(卢芳云) 1, TANG Fu-jing (汤福静... results, a simplified method and a semi analytical equation for deriving the P-I diagram are proposed for different failure modes and damage levels.Key words:blast load; failure mode; pressure-impulse......
EVALUATION OF THE TIME DEPENDENT FAILURE ASSESSMENT CURVES FOR 10CrMo910 AND 316 SS AT 550℃ S.D.Tu1,Z.D.Wang1,F.Z.Xuan1,C.W.Ma1 (1.School of Mechanical Engineering, East China University of Science... curves and time-dependent failure assessment curves of the two materials were given. Finally, the formulae of time dependent failure assessment curve for 10CrMo910 and 316 stainless steel corresponding......
with the fracture toughness of the material for damage tolerance analysis. Also a failure assessment diagram is drawn for welded 7075-T7351 aluminum alloy plates with different crack sizes for as-welded (only... finite element analysis [6] is used. Failure assessment diagram is also drawn for welded 7075-T7351 aluminium alloy plates with different crack sizes for as-welded (only residual stress, RS), 50 MPa......
[22] modelled slide-head-toppling failure using the finite element method. HAGHGOUEI et al [21] presented an analytical solution for the assessment of toppling- slumping failure. The slide-toe-toppling...), this comparison is illustrated in Table 6. Since the tilting table of the experimental tests had a variable inclination, the inclination angle at the moment of failure was chosen for more assessment. In Table......
......
of the variable weight model based on MFIM and TOPSIS is shown in detail in Figure 3. Figure 3 Diagram of MFIM-TOPSIS evaluation model 4 Engineering application 4.1 Risk assessment of floor water inrush... of Failure Analysis and Prevention, 2017, 17(5): 989-1010. DOI: 10.1007/s11668-017-0325-0. [30] WANG Ying-chao, OLGUN C G, WANG Lin-bing, MENG Bo. Risk assessment of water inrush in karst tunnels based......