共搜索到268条信息,每页显示10条信息,共27页。用时:0小时0分0秒578毫秒
J. Cent. South Univ. Technol. (2007)01-0073-05 DOI: 10.1007/s11771-007-0015-2 New amperometric glucose biosensor by entrapping glucose oxidase into chitosan/nanoporous ZrO2/multiwalled carbon nanotubes nanocomposite film WEI Wan-zhi(魏万之)1, ZHAI Xiu-rong(翟秀荣)2, ZENG Jin-xiang(曾金祥)1, GAO Yan......
Determination of trace mercury in compost extract by inhibition based glucose oxidase biosensor LIU Jian-xiao(刘剑潇)1, XU Xiang-min(徐祥民)1, 2, TANG Lin(汤 琳)2, ZENG Guang-ming(曾光明)1...; Abstract: A novel inhibition based biosensor of glucose oxidase(GOx) for environmental mercury detection was developed. An electropolymerized aniline membrane was prepared......
J. Cent. South Univ. (2012) 19: 2125-2129 DOI: 10.1007/s11771-012-1254-4 Effect of OH- on morphology of Cu2O particles prepared through reduction of Cu(II) by glucose WANG Yue-jun(王岳俊), ZHOU Kang-gen... particles with different shapes were prepared via reducing Cu(II) in alkaline system by glucose at 50 ℃. The products were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM......
......
-free glucose sensor ZHANG Yin-he(张银河)1, HUANG Su-ping(黄苏萍)1, XIAO Qi(肖奇)2 1. State Key Lab of Powder Metallurgy, Central South University, Changsha 410083, China; 2. School of Minerals Processing... spectroscopy revealed that both Ni-O and Fe-O bonds were formed on the surface of the as-prepared electrode. Moreover, the iron element decorated Ni foam electrode can be used as non-enzymatic glucose......
J. Cent. South Univ. Technol. (2009) 16: 0982-0986 DOI: 10.1007/s11771-009-0163-7 Non-invasive glucose measuring apparatus based on conservation of energy method CHEN Zhen-cheng(陈真诚), JIN Xing...; Abstract: A new non-invasive blood glucose......
J. Cent. South Univ. (2019) 26: 2974-2986 DOI: https://doi.org/10.1007/s11771-019-4229-x Enhanced HMF yield from glucose with H-ZSM-5 catalyst in water... and Springer-Verlag GmbH Germany, part of Springer Nature 2019 Abstract: With the aim of achieving a high 5-hydroxymethylfurfural (HMF) yield from glucose with H-ZSM-5 catalyst at low cost, three......
; Preparation of lactic acid from glucose...; Abstract: A new reaction system was designed to economically convert glucose to lactic acid environment-friendly. Hydrophobic ionic liquids were chosen as solvent......
A graphene-laminated electrode with high glucose oxidase loading for highly-sensitive glucose detectionYabin Hao1,2,Minghe Fang1,2,Chuan Xu1,Zhe Ying1,Han Wang1,2,Rui Zhang3,Hui-Ming Cheng1,2,4,You... considerable attention for glucose detection because of high surface area, abundant functional groups, and good biocompatibility. Defects and functional groups of the GO are beneficial......
Transfer-free CVD graphene for highly sensitive glucose sensorsShijing Wei1,2,3,4,Yabin Hao1,5,Zhe Ying1,Chuan Xu1,Qinwei Wei1,5,Sen Xue1,6,Hui-Ming Cheng1,2,5,7,Wencai Ren1,5,Lai-Peng Ma1,5,You...="ChDivSummary" name="ChDivSummary">Chemical vapor deposition(CVD) graphene film is a promising electrode-modifying material for fabricating high-performance glucose sensor due to its high electrical......