摘    要:建立了利用电感耦合等离子体质谱法(ICP-MS)同时测定铸铁中镁、锡、镧、铈、锑和铅元素含量的分析方法,并对ICP-MS工作参数进行了优化。在优化仪器条件的基础上,选择合适的测量同位素消除了质谱干扰;使用混合内标Sc、In、Bi很好地校正了基体效应和仪器信号漂移。各元素方法检出限分别为Mg(1.1 ng/mL),Sn(0.3 ng/mL),La(0.03 ng/mL),Ce(0.04 ng/mL),Pb(0.08 ng/mL),Sb(0.4 ng/mL)。采用该方法对标准样品和实际样品进行了分析,结果表明精密度和准确度均能满足分析要求。

Abstract: A method for simultaneous determination of Mg,Sn,La,Ce,Sb and Pb in cast iron by inductively coupled plasma mass spectrometry (ICP-MS) was established,and the instrument working conditions were optimized.Under the optimized operation conditions,the spectral interference could be eliminated by selecting appropriate analytical isotopes,and meanwhile,the matrix effect and signal shift could be corrected effectively by using mixed internal standard elements of Sc,In and Bi.The detection limit of Mg,Sn,La,Ce,Pb and Sb were 1.1,0.3,0.03,0.04,0.08,and 0.4 ng/mL,respectively.The method has been applied to the determination of certified reference materials and actual samples.The results indicated that its accuracy and precision could meet the demand for analysis.

详情信息展示

电感耦合等离子体质谱法测定铸铁中镁、锡、镧、铈、锑和铅

亢德华1,于媛君1,王铁1,杨丽荣1,顾继红1

(1.辽宁省鞍山市鞍钢股份有限公司技术中心)

摘 要:建立了利用电感耦合等离子体质谱法(ICP-MS)同时测定铸铁中镁、锡、镧、铈、锑和铅元素含量的分析方法,并对ICP-MS工作参数进行了优化。在优化仪器条件的基础上,选择合适的测量同位素消除了质谱干扰;使用混合内标Sc、In、Bi很好地校正了基体效应和仪器信号漂移。各元素方法检出限分别为Mg(1.1 ng/mL),Sn(0.3 ng/mL),La(0.03 ng/mL),Ce(0.04 ng/mL),Pb(0.08 ng/mL),Sb(0.4 ng/mL)。采用该方法对标准样品和实际样品进行了分析,结果表明精密度和准确度均能满足分析要求。

关键词:电感耦合等离子体质谱法; 铸铁; 镁; 锡; 镧; 铈; 锑; 铅

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号