简介概要

Influence factors of capacity loss after short-time standing of metal-hydride electrode and its EIS model

来源期刊:Journal of Rare Earths2013年第8期

论文作者:王倩楠 晁栋梁 周万海 陈云贵 吴朝玲

文章页码:772 - 777

摘    要:Considerable irreversible capacity loss was observed after the electrode standing at small state-of-charge (SOC) for only a short term. Influence of SOC, standing time and the replacement elements of LaNi5-type hydrogen storage alloys to standing was discussed. Charge-transfer resistance, exchange current density (I0 ), and hydrogen diffusion coefficient were determined based on the study of electrochemical impedance spectrum (EIS), linear polarization (LP) and constant potential step (CPS), respectively. The oxidation of metal Ni on the alloy surface after standing was responsible for the rapid deterioration of capacity, charge-transfer resistance and I0 . Galvanostatic, LP, EIS and CPS measurements suggested the presence of an oxide and/or corrosion layer on the alloy surface of raw material and electrode after standing at 0% SOC for 2 d. It was proved that the first small semicircle in high-frequency region of EIS was related to this layer. Novel EIS model in metal hydride electrode was proposed accordingly.

详情信息展示

Influence factors of capacity loss after short-time standing of metal-hydride electrode and its EIS model

王倩楠,晁栋梁,周万海,陈云贵,吴朝玲

College of Materials Science and Engineering, Sichuan University

摘 要:Considerable irreversible capacity loss was observed after the electrode standing at small state-of-charge (SOC) for only a short term. Influence of SOC, standing time and the replacement elements of LaNi5-type hydrogen storage alloys to standing was discussed. Charge-transfer resistance, exchange current density (I0 ), and hydrogen diffusion coefficient were determined based on the study of electrochemical impedance spectrum (EIS), linear polarization (LP) and constant potential step (CPS), respectively. The oxidation of metal Ni on the alloy surface after standing was responsible for the rapid deterioration of capacity, charge-transfer resistance and I0 . Galvanostatic, LP, EIS and CPS measurements suggested the presence of an oxide and/or corrosion layer on the alloy surface of raw material and electrode after standing at 0% SOC for 2 d. It was proved that the first small semicircle in high-frequency region of EIS was related to this layer. Novel EIS model in metal hydride electrode was proposed accordingly.

关键词:

<上一页 1 下一页 >

相关论文

  • 暂无!

相关知识点

  • 暂无!

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com