Failure characteristics of Ag-SnO2 contact material in AC level

来源期刊:Rare Metals2008年第1期

论文作者:MENG Fanbina,b,LU Jianguoa,ZHU Yongqinga,b,LU Ningyib,CHEN Zhichaob,and HUANG Qiutaob a Electrical Apparatus Institute,Hebei University of Technology,Tianjin ,China b Hongfa Electroacoustic Co.Ltd.,Xiamen ,China

文章页码:18 - 21

摘    要:The failure characteristics of the contact material Ag-SnO2 were investigated by X-ray diffraction(XRD),scanning electron microscopy(SEM),and X-ray energy dispersive spectroscopy(EDS).Phase analysis showed that there were Ag,SnO2,and Sn on the contact surfaces at the time of failure under the load condition of 30 A and 220 V(AC),which means that SnO2 decomposed in service.When the contacts were tested under airproof ambient condition,half-spherical bulges came into being on the contact surfaces,which resulted in early failure and dispersive characteristics.But half-spherical bulges were not found when the contacts were tested under open ambient condition.The temperature change of the contacts during the life testing under airproof ambient condition was different from that under open ambient condition.

详情信息展示

Failure characteristics of Ag-SnO2 contact material in AC level

MENG Fanbina,b,LU Jianguoa,ZHU Yongqinga,b,LU Ningyib,CHEN Zhichaob,and HUANG Qiutaob a Electrical Apparatus Institute,Hebei University of Technology,Tianjin 300130,China b Hongfa Electroacoustic Co.Ltd.,Xiamen 361021,China

摘 要:The failure characteristics of the contact material Ag-SnO2 were investigated by X-ray diffraction(XRD),scanning electron microscopy(SEM),and X-ray energy dispersive spectroscopy(EDS).Phase analysis showed that there were Ag,SnO2,and Sn on the contact surfaces at the time of failure under the load condition of 30 A and 220 V(AC),which means that SnO2 decomposed in service.When the contacts were tested under airproof ambient condition,half-spherical bulges came into being on the contact surfaces,which resulted in early failure and dispersive characteristics.But half-spherical bulges were not found when the contacts were tested under open ambient condition.The temperature change of the contacts during the life testing under airproof ambient condition was different from that under open ambient condition.

关键词:

<上一页 1 下一页 >

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号