MULTI-PEAK MATCH INTENSITY RATIO METHOD OF QUANTITATIVE X-RAY DIFFRACTION PHASE ANALYSIS

来源期刊:Acta Metallurgica Sinica2003年第6期

论文作者:G.Chu H.J.You Y.F.Cong

Key words:X-ray diffraction; multi-peak match intensity ratio; quantitative phase analysis;

Abstract: A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.

详情信息展示

MULTI-PEAK MATCH INTENSITY RATIO METHOD OF QUANTITATIVE X-RAY DIFFRACTION PHASE ANALYSIS

G.Chu1,H.J.You1,Y.F.Cong1

(1.Research Center of Analysis and Test, Liaoning University of Petroleum & Chemical Technology, Fushun 113001, China)

Abstract:A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.

Key words:X-ray diffraction; multi-peak match intensity ratio; quantitative phase analysis;