简介概要

A Fiber Optic Sensor for 2,4-dichlorophenol Analysis based on Optical Composite Oxygen-sensitive Film

来源期刊:Journal Of Wuhan University Of Technology Materials Science Edition2020年第4期

论文作者:童伊琳 ZENG Zhihong 俞侃 BAO Jiaqi Yin Juanjuan

文章页码:743 - 749

摘    要:A novel fiber optic sensor based on optical composite oxygen-sensitive film was developed for determination of 2,4-dichlorophenol (DCP).The optical composite oxygen-sensitive film consists of tris(2,2’-bipyridyl) dichloro ruthenium(II) hexahydrate (Ru(bpy)3Cl2) as the fluorescence indicator and iron(III) tetrasulfophthalocyanine (Fe(III)PcTs) as bionic enzyme.A lock-in amplifier was used for detecting the lifetime of the composite oxygen-sensitive film by measuring the phase delay of the sensor head.The different variables affecting the sensor performance were evaluated and optimized.Under the optimal conditions (i e,pH 6.0,25 ℃,Fe(III)PcTs concentration of 5.0×10-5 mol/L),the linear detection range,detection limit and response time of the fiber optic sensor are 3.0×10-7-9.0×10-5 mol/L,4.8×10-8 mol/L(S/N=3),and 220 s,respectively.The sensor displays high selectivity,good repeatability and stability,which have good potentials in analyzing DCP concentration in practical water samples.

详情信息展示

A Fiber Optic Sensor for 2,4-dichlorophenol Analysis based on Optical Composite Oxygen-sensitive Film

童伊琳,ZENG Zhihong,俞侃,BAO Jiaqi,Yin Juanjuan

Information Science and Technology Department, Wenhua College

摘 要:A novel fiber optic sensor based on optical composite oxygen-sensitive film was developed for determination of 2,4-dichlorophenol (DCP).The optical composite oxygen-sensitive film consists of tris(2,2’-bipyridyl) dichloro ruthenium(II) hexahydrate (Ru(bpy)3Cl2) as the fluorescence indicator and iron(III) tetrasulfophthalocyanine (Fe(III)PcTs) as bionic enzyme.A lock-in amplifier was used for detecting the lifetime of the composite oxygen-sensitive film by measuring the phase delay of the sensor head.The different variables affecting the sensor performance were evaluated and optimized.Under the optimal conditions (i e,pH 6.0,25 ℃,Fe(III)PcTs concentration of 5.0×10-5 mol/L),the linear detection range,detection limit and response time of the fiber optic sensor are 3.0×10-7-9.0×10-5 mol/L,4.8×10-8 mol/L(S/N=3),and 220 s,respectively.The sensor displays high selectivity,good repeatability and stability,which have good potentials in analyzing DCP concentration in practical water samples.

关键词:

<上一页 1 下一页 >

有色金属在线官网  |   会议  |   在线投稿  |   购买纸书  |   科技图书馆

中南大学出版社 技术支持 版权声明   电话:0731-88830515 88830516   传真:0731-88710482   Email:administrator@cnnmol.com

互联网出版许可证:(署)网出证(京)字第342号   京ICP备17050991号-6      京公网安备11010802042557号